Author : Mohamed Mohamed
CoAuthors : Y ABOUL-ENEIN, Mohammed GAMAL
Source : Gazi University Journal of Science
Date of Publication : 01/2015
Abstract :
ABSTRACT Accurate and sensitive spectrofluorimetric method was developed for
determination of diiodohydroxyquinoline in presence of metronidazole. In this method the
native fluorescence of diiodohydroxyquinoline in water solvent at λ= 495 nm when excitation
was at 250 nm is used for its determination. Linear correlation was obtained in the
concentration range of 400 to 900 ng mL-1. The proposed method was successfully applied
for determination of diiodohydroxyquinoline in bulk powder with mean accuracy of 100.21 ...
Download PDF