ALP autoclave
Automatic Operation
Can be conveniently operated anywhere by just plugging it in. Just closing the exhaust valve and pushing the start button, you get fully automatic performances from start to finish.
Timer begins to work only after the set pressure / temperature is reached, buzzer announces sterilizing (and drying) completion and electricity cuts off.
Automatic air exhaust valve guarantees reliable sterilization under pure steam exposure.
Space-saving up-opening lid:
The lid opens and closes lightly with one hand, yet securely due to the unique opening system and the self-closing silicon rubber gasket.
Due to the vertical design and the up-opening lid share minimum space.
This system protects you from steam contact.
One touch setting of sterilizing temperature
Before operating, you can select and set sterilizing temperature by the control knob. So you need not adjust it in sterilizing operation
Prevention of water lack
The sensitive thermostat mounted on the surface of immersion - type sheathed heater, cuts off immediately the electrical source in case of water lack, and the buzzer sounds continuously.(also red lamp goes on… except -DP models) And even after the chamber cooled, the heater does not operate until you reset the main switch (breaker).
Easy and plain maintenance
Easy operation, and less trouble and plain maintenance by the simple analogue control system.
back to top
Saengineeringy Cabinets Thermo
Perform daily applications safely and efficiently with simple-to-order Thermo Scientific™ Saengineeringy Cabinet Packages, which include: Cabinet; manual, adjustable height stands; factory installed UV light and one set of armrests. These saengineeringy cabinets deliver exceptional design and technology advancements such as superior protection with proprietary airflow design, exceptional ergonomics for a safe and comfortable environment, and outstanding energy efficiency for operational cost savings.
back to top
Gel Electrophoresis
Separate particular DNA and proteins fragments on the basis of size, electric charge and other physical properties.
back to top
Gel Documentation System(Gel Doc)
Imaging and documentation of nucleic acids and protein suspended within polyacrylamide of agarose gels.
back to top
Thermocycler – PCR
Amplify & multiply segments of DNA via polymerase chain reaction PCR technique.
back to top
Autoclave
Sterilize the microbiological tools and materials as culture media using moist heat.
back to top
Saengineeringy Cabinet
Used to provide sterile environment for tissue culture facility. Air is drawn through HEPA filter and blown in a very smooth laminar flow away in a vertical direction.
back to top
UV Spectrophotometer
Measures the sample concentrations as a function light intensity absorption.
back to top
Sensitive Balance
Used to determine samples’ weights up to 3 and 4 digits.
back to top
Deep freezer (-20 ˚C)
Freeze samples at -20˚ C, preserve bacteria and diagnostic kits and enzymes.
back to top
Refrigerator (-8˚C)
Used to keep samples at a temperature range from -4˚C - 8˚C.
back to top
Centrifuge and Micro Centrifuge
Used for separation and precipitation of mixed or turbid samples.
Water Bath
Incubate samples in water at a constant temperature over a period of time, warming reagents and melting substrates.
back to top
Vortex
Mix small volumes of liquids.
back to top
Dry Bath Incubator heat block
Provides a controlled dry heat environment for test tubes containing in-vitro diagnostic specimens or samples for quantitative or qualitative procedures.
back to top
Microwave
Heating or defrosting the lab materials e.g. melting agar .
back to top
Hot Air Oven
Sterilizing articles that can withstand high temperature e.g. glassware.
back to top
Incubator
Grow microbiological cultures.
back to top
Incubator
Incubate samples at chosen temperatures.
back to top